Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 297
Filtrar
1.
Nat Commun ; 15(1): 3152, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605064

RESUMO

While we recognize the prognostic importance of clinicopathological measures and circulating tumor DNA (ctDNA), the independent contribution of quantitative image markers to prognosis in non-small cell lung cancer (NSCLC) remains underexplored. In our multi-institutional study of 394 NSCLC patients, we utilize pre-treatment computed tomography (CT) and 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) to establish a habitat imaging framework for assessing regional heterogeneity within individual tumors. This framework identifies three PET/CT subtypes, which maintain prognostic value after adjusting for clinicopathologic risk factors including tumor volume. Additionally, these subtypes complement ctDNA in predicting disease recurrence. Radiogenomics analysis unveil the molecular underpinnings of these imaging subtypes, highlighting downregulation in interferon alpha and gamma pathways in the high-risk subtype. In summary, our study demonstrates that these habitat imaging subtypes effectively stratify NSCLC patients based on their risk levels for disease recurrence after initial curative surgery or radiotherapy, providing valuable insights for personalized treatment approaches.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/genética , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Estudos Retrospectivos
2.
Phys Med Biol ; 69(10)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38588671

RESUMO

Objective. A novel x-ray field produced by an ultrathin conical target is described in the literature. However, the optimal design for an associated collimator remains ambiguous. Current optimization methods using Monte Carlo calculations restrict the efficiency and robustness of the design process. A more generic optimization method that reduces parameter constraints while minimizing computational load is necessary. A numerical method for optimizing the longitudinal collimator hole geometry for a cylindrically-symmetrical x-ray tube is demonstrated and compared to Monte Carlo calculations.Approach. The x-ray phase space was modelled as a four-dimensional histogram differential in photon initial position, final position, and photon energy. The collimator was modeled as a stack of thin washers with varying inner radii. Simulated annealing was employed to optimize this set of inner radii according to various objective functions calculated on the photon flux at a specified plane.Main results. The analytical transport model used for optimization was validated against Monte Carlo calculations using Geant4 via its wrapper, TOPAS. Optimized collimators and the resulting photon flux profiles are presented for three focal spot sizes and five positions of the source. Optimizations were performed with multiple objective functions based on various weightings of precision, intensity, and field flatness metrics. Finally, a select set of these optimized collimators, plus a parallel-hole collimator for comparison, were modeled in TOPAS. The evolution of the radiation field profiles are presented for various positions of the source for each collimator.Significance. This novel optimization strategy proved consistent and robust across the range of x-ray tube settings regardless of the optimization starting point. Common collimator geometries were re-derived using this algorithm while simultaneously optimizing geometry-specific parameters. The advantages of this strategy over iterative Monte Carlo-based techniques, including computational efficiency, radiation source-specificity, and solution flexibility, make it a desirable optimization method for complex irradiation geometries.


Assuntos
Método de Monte Carlo , Raios X , Fótons , Modelos Teóricos
3.
Cancers (Basel) ; 16(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38473297

RESUMO

Docetaxel +/- ramucirumab remains the standard-of-care therapy for patients with metastatic non-small-cell lung cancer (NSCLC) after progression on platinum doublets and immune checkpoint inhibitors (ICIs). The aim of our study was to investigate whether the cancer gene mutation status was associated with clinical benefits from docetaxel +/- ramucirumab. We also investigated whether platinum/taxane-based regimens offered a better clinical benefit in this patient population. A total of 454 patients were analyzed (docetaxel +/- ramucirumab n=381; platinum/taxane-based regimens n=73). Progression-free survival (PFS) and overall survival (OS) were compared among different subpopulations with different cancer gene mutations and between patients who received docetaxel +/- ramucirumab versus platinum/taxane-based regimens. Among patients who received docetaxel +/- ramucirumab, the top mutated cancer genes included TP53 (n=167), KRAS (n=127), EGFR (n=65), STK11 (n=32), ERBB2 (HER2) (n=26), etc. None of these cancer gene mutations or PD-L1 expression was associated with PFS or OS. Platinum/taxane-based regimens were associated with a significantly longer mQS (13.00 m, 95% Cl: 11.20-14.80 m versus 8.40 m, 95% Cl: 7.12-9.68 m, LogRank P=0.019) than docetaxel +/- ramcirumab. Key prognostic factors including age, histology, and performance status were not different between these two groups. In conclusion, in patients with metastatic NSCLC who have progressed on platinum doublets and ICIs, the clinical benefit from docetaxel +/- ramucirumab is not associated with the cancer gene mutation status. Platinum/taxane-based regimens may offer a superior clinical benefit over docetaxel +/- ramucirumab in this patient population.

4.
Cell Rep Med ; 5(3): 101463, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471502

RESUMO

[18F]Fluorodeoxyglucose positron emission tomography (FDG-PET) and computed tomography (CT) are indispensable components in modern medicine. Although PET can provide additional diagnostic value, it is costly and not universally accessible, particularly in low-income countries. To bridge this gap, we have developed a conditional generative adversarial network pipeline that can produce FDG-PET from diagnostic CT scans based on multi-center multi-modal lung cancer datasets (n = 1,478). Synthetic PET images are validated across imaging, biological, and clinical aspects. Radiologists confirm comparable imaging quality and tumor contrast between synthetic and actual PET scans. Radiogenomics analysis further proves that the dysregulated cancer hallmark pathways of synthetic PET are consistent with actual PET. We also demonstrate the clinical values of synthetic PET in improving lung cancer diagnosis, staging, risk prediction, and prognosis. Taken together, this proof-of-concept study testifies to the feasibility of applying deep learning to obtain high-fidelity PET translated from CT.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Tomografia Computadorizada por Raios X , Prognóstico
6.
Phys Med Biol ; 69(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38091616

RESUMO

Objective. In this multicentric collaborative study, we aimed to verify whether the selected radiation detectors satisfy the requirements of TRS-483 Code of Practice for relative small field dosimetry in megavoltage photon beams used in radiotherapy, by investigating four dosimetric characteristics. Furthermore, we intended to analyze and complement the recommendations given in TRS-483.Approach. Short-term stability, dose linearity, dose-rate dependence, and leakage were determined for 17 models of detectors considered suitable for small field dosimetry. Altogether, 47 detectors were used in this study across ten institutions. Photon beams with 6 and 10 MV, with and without flattening filters, generated by Elekta Versa HDTMor Varian TrueBeamTMlinear accelerators, were used.Main results. The tolerance level of 0.1% for stability was fulfilled by 70% of the data points. For the determination of dose linearity, two methods were considered. Results from the use of a stricter method show that the guideline of 0.1% for dose linearity is not attainable for most of the detectors used in the study. Following the second approach (squared Pearson's correlation coefficientr2), it was found that 100% of the data fulfill the criteriar2> 0.999 (0.1% guideline for tolerance). Less than 50% of all data points satisfied the published tolerance of 0.1% for dose-rate dependence. Almost all data points (98.2%) satisfied the 0.1% criterion for leakage.Significance. For short-term stability (repeatability), it was found that the 0.1% guideline could not be met. Therefore, a less rigorous criterion of 0.25% is proposed. For dose linearity, our recommendation is to adopt a simple and clear methodology and to define an achievable tolerance based on the experimental data. For dose-rate dependence, a realistic criterion of 1% is proposed instead of the present 0.1%. Agreement was found with published guidelines for background signal (leakage).


Assuntos
Aceleradores de Partículas , Radiometria , Radiometria/métodos , Fótons
7.
Med Phys ; 51(1): 447-463, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947472

RESUMO

BACKGROUND: Carbon nanotube-based cold cathode technology has revolutionized the miniaturization of X-ray tubes. However, current applications of these devices required optimization for large, uniform fields with low intensity. PURPOSE: This work investigated the feasibility and radiological characteristics of a novel conical X-ray target optimized for high intensity and high directionality to be used in a compact X-ray tube. METHODS: The proposed device uses an ultrathin, conical tungsten-diamond target that exhibits significant heat loading while maintaining a small focal spot size and promoting forward-directedness of the X-ray field through preferential attenuation of oblique-angled photons. The electrostatic and thermal properties of the theoretical tube were calculated and analyzed using COMSOL Multiphysics software. The production, transport, and calculation of radiological properties associated with the resultant X-ray field were performed using the Geant4 toolkit via its wrapper, TOPAS. RESULTS: Heat transfer analysis of this X-ray tube demonstrated the feasibility of a 200-kV electron beam bombarding the proposed target at a maximum current of 100 mA using a 1-ms symmetric duty cycle. The cathode of the X-ray tube was designed to be segmented into nine switchable electrical segments for modulation of the focal spot size from 0.4- to 10.8-mm. After importing the COMSOL-derived electron beam into TOPAS for X-ray production simulations, radiological analysis of the resultant field demonstrated high levels of intrinsic beam collimation while maintaining high intensity. A maximum dose rate of 17,887 cGy/min was calculated for 1-mm depth in water at 7-cm distance. CONCLUSIONS: The proposed X-ray tube design can create highly directional X-ray fields with superior fluence compared to that of current commercial X-ray tubes of comparable size.


Assuntos
Nanotubos de Carbono , Raios X , Radiografia , Fluoroscopia , Software , Método de Monte Carlo
8.
Semin Radiat Oncol ; 34(1): 135-144, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38105088

RESUMO

Magnetic resonance image guided radiation therapy (MRIgRT) is a relatively new technology that has already shown outcomes benefits but that has not yet reached its clinical potential. The improved soft-tissue contrast provided with MR, coupled with the immediacy of image acquisition with respect to the treatment, enables expansion of on-table adaptive protocols, currently at a cost of increased treatment complexity, use of human resources, and longer treatment slot times, which translate to decreased throughput. Many approaches are being investigated to meet these challenges, including the development of artificial intelligence (AI) algorithms to accelerate and automate much of the workflow and improved technology that parallelizes workflow tasks, as well as improvements in image acquisition speed and quality. This article summarizes limitations of current available integrated MRIgRT systems and gives an outlook about scientific developments to further expand the use of MRIgRT.


Assuntos
Inteligência Artificial , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Fluxo de Trabalho
9.
JCO Clin Cancer Inform ; 7: e2300136, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38055914

RESUMO

In August 2022, the Cancer Informatics for Cancer Centers brought together cancer informatics leaders for its biannual symposium, Precision Medicine Applications in Radiation Oncology, co-chaired by Quynh-Thu Le, MD (Stanford University), and Walter J. Curran, MD (GenesisCare). Over the course of 3 days, presenters discussed a range of topics relevant to radiation oncology and the cancer informatics community more broadly, including biomarker development, decision support algorithms, novel imaging tools, theranostics, and artificial intelligence (AI) for the radiotherapy workflow. Since the symposium, there has been an impressive shift in the promise and potential for integration of AI in clinical care, accelerated in large part by major advances in generative AI. AI is now poised more than ever to revolutionize cancer care. Radiation oncology is a field that uses and generates a large amount of digital data and is therefore likely to be one of the first fields to be transformed by AI. As experts in the collection, management, and analysis of these data, the informatics community will take a leading role in ensuring that radiation oncology is prepared to take full advantage of these technological advances. In this report, we provide highlights from the symposium, which took place in Santa Barbara, California, from August 29 to 31, 2022. We discuss lessons learned from the symposium for data acquisition, management, representation, and sharing, and put these themes into context to prepare radiation oncology for the successful and safe integration of AI and informatics technologies.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Humanos , Inteligência Artificial , Informática , Neoplasias/diagnóstico , Neoplasias/radioterapia
11.
Nat Cancer ; 4(9): 1228-1238, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37749355

RESUMO

The pace of technological innovation over the past three decades has transformed the field of radiotherapy into one of the most technologically intense disciplines in medicine. However, the global barriers to access this highly effective treatment are complex and extend beyond technological limitations. Here, we review the technological advancement and current status of radiotherapy and discuss the efforts of the global radiation oncology community to formulate a more integrative 'diagonal approach' in which the agendas of science-driven advances in individual outcomes and the sociotechnological task of global cancer control can be aligned to bring the benefit of this proven therapy to patients with cancer everywhere.


Assuntos
Medicina , Neoplasias , Radioterapia (Especialidade) , Humanos , Neoplasias/radioterapia , Tecnologia
12.
Patterns (N Y) ; 4(8): 100777, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37602223

RESUMO

Survival models exist to study relationships between biomarkers and treatment effects. Deep learning-powered survival models supersede the classical Cox proportional hazards (CoxPH) model, but substantial performance drops were observed on high-dimensional features because of irrelevant/redundant information. To fill this gap, we proposed SwarmDeepSurv by integrating swarm intelligence algorithms with the deep survival model. Furthermore, four objective functions were designed to optimize prognostic prediction while regularizing selected feature numbers. When testing on multicenter sets (n = 1,058) of four different cancer types, SwarmDeepSurv was less prone to overfitting and achieved optimal patient risk stratification compared with popular survival modeling algorithms. Strikingly, SwarmDeepSurv selected different features compared with classical feature selection algorithms, including the least absolute shrinkage and selection operator (LASSO), with nearly no feature overlapping across these models. Taken together, SwarmDeepSurv offers an alternative approach to model relationships between radiomics features and survival endpoints, which can further extend to study other input data types including genomics.

13.
JCO Glob Oncol ; 9: e2200431, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37471671

RESUMO

PURPOSE: Automation, including the use of artificial intelligence, has been identified as a possible opportunity to help reduce the gap in access and quality for radiotherapy and other aspects of cancer care. The Radiation Planning Assistant (RPA) project was conceived in 2015 (and funded in 2016) to use automated contouring and treatment planning algorithms to support the efforts of oncologists in low- and middle-income countries, allowing them to scale their efforts and treat more patients safely and efficiently (to increase access). DESIGN: In this review, we discuss the development of the RPA, with a particular focus on clinical acceptability and safety/risk across jurisdictions as these are important indicators for the successful future deployment of the RPA to increase radiotherapy availability and ameliorate global disparities in access to radiation oncology. RESULTS: RPA tools will be offered through a webpage, where users can upload computed tomography data sets and download automatically generated contours and treatment plans. All interfaces have been designed to maximize ease of use and minimize risk. The current version of the RPA includes automated contouring and planning for head and neck cancer, cervical cancer, breast cancer, and metastases to the brain. CONCLUSION: The RPA has been designed to bring high-quality treatment planning to more patients across the world, and it may encourage greater investment in treatment devices and other aspects of cancer treatment.


Assuntos
Neoplasias da Mama , Radioterapia (Especialidade) , Humanos , Feminino , Planejamento da Radioterapia Assistida por Computador/métodos , Inteligência Artificial , Neoplasias da Mama/patologia , Automação
14.
Lancet Digit Health ; 5(7): e404-e420, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37268451

RESUMO

BACKGROUND: Only around 20-30% of patients with non-small-cell lung cancer (NCSLC) have durable benefit from immune-checkpoint inhibitors. Although tissue-based biomarkers (eg, PD-L1) are limited by suboptimal performance, tissue availability, and tumour heterogeneity, radiographic images might holistically capture the underlying cancer biology. We aimed to investigate the application of deep learning on chest CT scans to derive an imaging signature of response to immune checkpoint inhibitors and evaluate its added value in the clinical context. METHODS: In this retrospective modelling study, 976 patients with metastatic, EGFR/ALK negative NSCLC treated with immune checkpoint inhibitors at MD Anderson and Stanford were enrolled from Jan 1, 2014, to Feb 29, 2020. We built and tested an ensemble deep learning model on pretreatment CTs (Deep-CT) to predict overall survival and progression-free survival after treatment with immune checkpoint inhibitors. We also evaluated the added predictive value of the Deep-CT model in the context of existing clinicopathological and radiological metrics. FINDINGS: Our Deep-CT model demonstrated robust stratification of patient survival of the MD Anderson testing set, which was validated in the external Stanford set. The performance of the Deep-CT model remained significant on subgroup analyses stratified by PD-L1, histology, age, sex, and race. In univariate analysis, Deep-CT outperformed the conventional risk factors, including histology, smoking status, and PD-L1 expression, and remained an independent predictor after multivariate adjustment. Integrating the Deep-CT model with conventional risk factors demonstrated significantly improved prediction performance, with overall survival C-index increases from 0·70 (clinical model) to 0·75 (composite model) during testing. On the other hand, the deep learning risk scores correlated with some radiomics features, but radiomics alone could not reach the performance level of deep learning, indicating that the deep learning model effectively captured additional imaging patterns beyond known radiomics features. INTERPRETATION: This proof-of-concept study shows that automated profiling of radiographic scans through deep learning can provide orthogonal information independent of existing clinicopathological biomarkers, bringing the goal of precision immunotherapy for patients with NSCLC closer. FUNDING: National Institutes of Health, Mark Foundation Damon Runyon Foundation Physician Scientist Award, MD Anderson Strategic Initiative Development Program, MD Anderson Lung Moon Shot Program, Andrea Mugnaini, and Edward L C Smith.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Aprendizado Profundo , Neoplasias Pulmonares , Estados Unidos , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Antígeno B7-H1 , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/uso terapêutico , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico
15.
Front Oncol ; 13: 1129380, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36925929

RESUMO

Machine learning-based tools are capable of guiding individualized clinical management and decision-making by providing predictions of a patient's future health state. Through their ability to model complex nonlinear relationships, ML algorithms can often outperform traditional statistical prediction approaches, but the use of nonlinear functions can mean that ML techniques may also be less interpretable than traditional statistical methodologies. While there are benefits of intrinsic interpretability, many model-agnostic approaches now exist and can provide insight into the way in which ML systems make decisions. In this paper, we describe how different algorithms can be interpreted and introduce some techniques for interpreting complex nonlinear algorithms.

16.
Diagnostics (Basel) ; 13(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36832155

RESUMO

Developers and users of artificial-intelligence-based tools for automatic contouring and treatment planning in radiotherapy are expected to assess clinical acceptability of these tools. However, what is 'clinical acceptability'? Quantitative and qualitative approaches have been used to assess this ill-defined concept, all of which have advantages and disadvantages or limitations. The approach chosen may depend on the goal of the study as well as on available resources. In this paper, we discuss various aspects of 'clinical acceptability' and how they can move us toward a standard for defining clinical acceptability of new autocontouring and planning tools.

17.
Radiother Oncol ; 182: 109577, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36841341

RESUMO

AIM OF THE STUDY: To elucidate the important factors and their interplay that drive performance on IMRT phantoms from the Imaging and Radiation Oncology Core (IROC). METHODS: IROC's IMRT head and neck phantom contains two targets and an organ at risk. Point and 2D dose are measured by TLDs and film, respectively. 1,542 irradiations between 2012-2020 were retrospectively analyzed based on output parameters, complexity metrics, and treatment parameters. Univariate analysis compared parameters based on pass/fail, and random forest modeling was used to predict output parameters and determine the underlying importance of the variables. RESULTS: The average phantom pass rate was 92% and has not significantly improved over time. The step-and-shoot irradiation technique had significantly lower pass rates that significantly affected other treatment parameters' pass rates. The complexity of plans has significantly increased with time, and all aperture-based complexity metrics (except MCS) were associated with the probability of failure. Random forest-based prediction of failure had an accuracy of 98% on held-out test data not used in model training. While complexity metrics were the most important contributors, the specific metric depended on the set of treatment parameters used during the irradiation. CONCLUSION: With the prevalence of errors in radiotherapy, understanding which parameters affect treatment delivery is vital to improve patient treatment. Complexity metrics were strongly predictive of irradiation failure; however, they are dependent on the specific treatment parameters. In addition, the use of one complexity metric is insufficient to monitor all aspects of the treatment plan.


Assuntos
Radioterapia (Especialidade) , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Aprendizado de Máquina
18.
Med Phys ; 50 Suppl 1: 54-57, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36681876

RESUMO

The development of cone-beam CT guided radiotherapy has transformed radiation oncology in the 20 years since it was first released commercially. The technological pace of change has spurred a massive transformation in our daily clinical practice, forced us to evolve our approach to multi- and inter-disciplinary collaboration, and enabled new treatment paradigms. Further progress in integrating quantitative CT in these robotic platforms promises to do even more by "burying the complexity" of radiotherapy and leveraging the expanding digital fabric that uses machine learning approaches to bring semi-automated expertise to bear on the issues of expertise and quality. This is the only way we will be able to respond to the massive global shortfall in high-quality radiotherapy services across the globe.


Assuntos
Radioterapia Guiada por Imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas
19.
Phys Imaging Radiat Oncol ; 25: 100415, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36718356

RESUMO

As frameless stereotactic radiosurgery increase in use, the aim of this study was to evaluate intra-fraction motion through cone-beam CT (CBCT) and high-definition motion management (HDMM) systems. Intra-fraction motion measured between localization, repeat localization and post-treatment CBCTs were correlated to intra-faction motion indicated by the HDMM files using the Pearson coefficient (r). A total of 302 plans were reviewed from 263 patients (114 male, 149 female); 216 pairs of localization-repeat localization, and 260 localization-post-treatment CBCTs were analyzed against HDMM logs. We found the magnitude of intra-fraction motion detected by the HDMM system were larger than the corresponding CBCT results.

20.
Phys Med Biol ; 67(24)2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36541560

RESUMO

Tumours exhibit abnormal interstitial structures and vasculature function often leading to impaired and heterogeneous drug delivery. The disproportionate spatial accumulation of a drug in the interstitium is determined by several microenvironmental properties (blood vessel distribution and permeability, gradients in the interstitial fluid pressure). Predictions of tumour perfusion are key determinants of drug delivery and responsiveness to therapy. Pharmacokinetic models allow for the quantification of tracer perfusion based on contrast enhancement measured with non-invasive imaging techniques. An advanced cross-voxel exchange model (CVXM) was recently developed to provide a comprehensive description of tracer extravasation as well as advection and diffusion based on cross-voxel tracer kinetics (Sinnoet al2021). Transport parameters were derived from DCE-MRI of twenty TS-415 human cervical carcinoma xenografts by using CVXM. Tracer velocity flows were measured at the tumour periphery (mean 1.78-5.82µm.s-1) pushing the contrast outward towards normal tissue. These elevated velocity measures and extravasation rates explain the heterogeneous distribution of tracer across the tumour and its accumulation at the periphery. Significant values for diffusivity were deduced across the tumours (mean 152-499µm2.s-1). CVXM resulted in generally smaller values for the extravasation parameterKext(mean 0.01-0.04 min-1) and extravascular extracellular volume fractionve(mean 0.05-0.17) compared to the standard Tofts parameters, suggesting that Toft model underestimates the effects of inter-voxel exchange. The ratio of Tofts' extravasation parameters over CVXM's was significantly positively correlated to the cross-voxel diffusivity (P< 0.0001) and velocity (P= 0.0005). Tofts' increasedvemeasurements were explained using Sinnoet al(2021)'s theoretical work. Finally, a scan time of 15 min renders informative estimations of the transport parameters. However, a duration as low as 7.5 min is acceptable to recognize the spatial variation of transport parameters. The results demonstrate the potential of utilizing CVXM for determining metrics characterizing the exchange of tracer between the vasculature and the tumour tissue. Like for many earlier models, additional work is strongly recommended, in terms of validation, to develop more confidence in the results, motivating future laboratory work in this regard.


Assuntos
Meios de Contraste , Neoplasias do Colo do Útero , Feminino , Humanos , Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Difusão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA